SynOne EMS — Energy Management

Meters · Demand · EV Billing · On-premise

SynOne EMS has its own product site with screens, modules and rollout details.

Visit synone.shengyiltd.com
Product catalogue (PDF)

Everything on this page — who it fits, architecture, functions and FAQ — as one PDF, with our contact details.

Download PDF

It reads the meters on site, logs energy every 15 minutes and estimates cost against Taipower’s time-of-use tariff. As demand nears the contract capacity it warns; past it, it sheds the lighting, outputs or air-conditioning you choose in order, and restores them once demand falls. In residential buildings, EV charging bays can be tied to households and meters and billed monthly from automatic readings.

WHO IT IS FOR
  • Buildings that want to know where the power goes
    • Office
    • Industrial

    Once multi-circuit meters are connected, per-circuit ranking and share, 15-minute load profiles and peak demand are on one screen, with CSV export.

  • Sites that keep exceeding their contract demand

    Set the contract capacity and shedding order; the dry run logs what it would shed without sending commands, so you can check the targets before switching it on.

  • Residential buildings where owners install EV chargers

    Each bay is tied to a household and a meter, billed by time-of-use rate, per-kWh mark-up and a monthly base fee, with meter swaps, manual readings and payments handled. Billing runs off the meter, so any charger brand works.

Meters are read directly over Modbus TCP or Modbus RTU over TCP (via an RS485 converter); the multi-circuit meters verified in practice are DAE’s SMB series, and meters on other protocols can come in through the SynOne gateway. Air-conditioning control currently supports the Midea XYE bus via a converter. Costs are time-of-use estimates — the Taipower bill is authoritative.

SYSTEM ARCHITECTURE

Meters are polled by the platform directly; devices on other protocols arrive through the gateway. The energy service logs, estimates and watches demand, sends control commands when it must shed, and remembers which devices it switched off.

On SiteMulti-circuit meters (Modbus)Lighting · outputsAir-con (XYE bus)SynOne EMSLive readings · offline flags15-min logs · TOU estimatesDemand watch · staged sheddingEV bay monthly billingUse and OutputDaily / monthly · load profileCSV exportHousehold EV billsEV fee beside management feesReadingsShed · restoreReportsBillsInstalled on site; after a restart the platform still knows which devices it shed, so none are left off.
PRODUCT SCREENS
SynOne EMS live meters (demo data)
Live readings: power, cumulative energy, voltage, current, power factor and frequency per circuit, with timed-out meters flagged on their own. Note: demo data.
SynOne EMS energy analysis (demo data)
Energy analysis: today’s 15-minute load curve and peak, with circuits ranked by usage, share, peak demand and estimated cost below. Note: demo data.
SynOne EMS demand (demo data)
Demand: contract capacity, live power and its share of the contract, and today’s and this month’s peaks; a warning appears near the threshold, and shedding only logs in dry-run mode. Note: demo data.
CORE FEATURES
  • New meters without new code

    Register maps live in configuration, so a new brand or extra circuits is a settings change; one meter going offline is flagged on its own without affecting the rest.

  • Time-of-use estimates

    Peak, mid-peak and off-peak, summer and non-summer, and public holidays are all accounted for; gaps longer than an hour are excluded rather than counted as usage.

  • Shedding with a dry run

    Demand shedding starts in dry-run mode, logging what it would have shed; real commands are enabled only after you have checked.

  • EV fees beside management fees

    Residents get a notification when an EV bill is issued, and the management-fee statement gains a charging column so the office can collect both together.

  • Prepaid charging, one session at a time

    Power to the bay is switched on only after the driver tops up at the guard desk, and the meter is read every 20 seconds to deduct the charge. When the balance runs out or the car is full, power is cut and the driver gets a text to move the car, with an idle fee after a grace period. Periods when the meter cannot be read are not charged — they are logged for review.

SPECIFICATIONS

EMS can be bought on its own or combined with building monitoring and property management on one platform.

  • Meter reading
    What it covers
    Power, kWh, voltage, current, power factor, frequency; offline flags
    Notes
    Modbus TCP and RTU over TCP; the screen refreshes every 10 seconds.
  • Energy reports
    What it covers
    15-minute logs, daily and monthly reports, load profile, circuit ranking and share, peak demand, CSV
    Notes
    Load profiles cover up to 31 days per query; statistics up to 400 days.
  • Demand control
    What it covers
    Contract capacity, near-limit warning, staged shedding of lighting / outputs / air-con, automatic restore
    Notes
    Demand is calculated from 15-minute energy deltas; dry run by default.
  • EV bay billing
    What it covers
    Bay tied to household and meter, automatic readings, TOU rate + per-kWh mark-up + base fee, meter swaps and manual entries, voids, payments, CSV
    Notes
    Billed from the meter; it does not control chargers and works with any brand.
  • Prepaid charging
    What it covers
    One record per session, top-up limits, deduction from the meter, power cut when spent or full, text to move the car, idle fee after a grace period, early pick-up settlement
    Notes
    Top-ups are cash at the guard desk; full-charge detection works with the Tesla Wall Connector; power is switched through a Modbus output, in dry run by default.
  • Air-con monitoring and control
    What it covers
    On/off, mode, temperature and fan per indoor unit; single or batch control, usable in schedules and demand shedding
    Notes
    Currently the Midea XYE bus via a converter.
FAQ
Can the cost figures be used as the bill?
We would not. The system estimates against Taipower’s time-of-use tariff for trends and comparisons between circuits; the Taipower bill is authoritative. Rates can be adjusted to your tariff plan.
Which meters are supported?
The platform reads Modbus TCP and Modbus RTU over TCP meters, with register maps in configuration. DAE’s SMB-series multi-circuit meters are verified; for other models send us the register table and we will set it up. Meters on other protocols can come in through the SynOne gateway.
Do residents need a particular charger brand?
No. Billing uses each bay’s meter reading and never talks to the charger, so any brand works. When a meter is offline, no rate is applied automatically for that period; staff enter the reading instead.
How is prepaid charging paid for?
For now the guard takes cash and tops up in the system, which then switches the bay on; online payment is not connected yet. Early pick-ups are settled by the guard. Before going live, power switching and text alerts are verified on site in dry-run mode.
Could shedding switch off something it should not?
You choose what can be shed and in what order, and it starts in dry-run mode that only logs. Once live, devices are restored automatically when demand falls, and the platform remembers what it switched off across restarts.
THE SYNONE SERIES

Each product can be bought on its own; on one SynOne platform they share accounts, alarms and the same people, door and device records.

Licensing

Sold under a perpetual licence for one site and one server, bound to that server’s hardware by a digitally signed licence file. Copying it to other machines or sites, reselling or lending it, reverse engineering it or circumventing the licence check is prohibited, and infringements are pursued under the Copyright Act. Full licence terms (Chinese) →